Borehole Pump Specialists

Case Studies

Golf Course Surrey

Site location: As above

Duration of works: (2 days) Commencing 24th January 2008 Completion 25th January 2008

Borehole information:

Casing PVC
Diameter 6”
Well depth 80m
Rest water level 13m
Rising main 11/2” Steel approx 60m deep
Dip Tube 1” PVC
Pump Type Lowara 6GS22 22kw
Performance 6m3/h at 80m

Problem

A while ago around 2006 we installed a borehole pump to supply the hotel and spa but over the last few months, it seemed to be producing a far lower flow- of bright orange water- than the 6m3/h it gave originally. We concluded that professional help was required and were recommended to contact Proquip Direct.

Cleaning Operation

Proquip made an initial visit to access the situation and found the flow to be only 4m3/h - concluding that the problem was caused by iron bacteria choking the well and pump.

They returned to treat the well one Thursday morning and added 70kg of their I-GON borehole cleaner to the water while circulating it back down the hole. They kept the pump running for an hour and then left it off overnight to allow the I-GON to dissolve the Iron Fouling. After 24hours the pump was re-started and the water run to waste for a couple of hours before testing the flow again. This was now found to be back to 6m3/h and the water was clear.

Conclusions

The cleaning of the borehole with I-GON achieved the desired results of removing the Iron Fouling from the pump and cleaning the screen….. we would be happy to recommend this treatment for anyone else with a well in a similar state.

Yours Sincerely
Mr Ian Odendaal
Technical Services Manager

Back to Case Studies...